    熱門關(guān)鍵詞:進口ELISA試劑盒,人ELISA試劑盒,大鼠elisa試劑盒價格,小鼠elisa試劑盒價格,豬elisa試劑盒,雞elisa試劑盒,兔elisa試劑盒,魚elsa試劑盒,其他種屬elisa試劑盒,豚鼠elisa試劑盒,倉鼠elisa試劑盒,裸鼠ELISA試劑盒,進口試劑,血清,動物血清,人血清,胎牛血清,氨基酸試劑,培養(yǎng)基,顯色培養(yǎng)基,大腸桿菌O157培養(yǎng)基,細菌總數(shù)培養(yǎng)基,金黃色葡萄球菌檢驗培養(yǎng)基,沙門氏菌/賀氏菌檢驗培養(yǎng)基, 弧菌檢驗培養(yǎng)基,其他培養(yǎng)基,酵母 霉菌 青霉 曲霉培養(yǎng)基, 李斯特氏菌檢驗培養(yǎng)基,抗體,二抗,一抗,生物試劑,酶生物試劑,蛋白質(zhì)試劑,抗生素試劑,植物激素及核酸試劑,碳水化合物試劑,色素試劑,維生素試劑,表面活性劑,緩沖試劑,其他生化試劑,標(biāo)準(zhǔn)品對照品類,對照品,對照藥材,標(biāo)準(zhǔn)品,標(biāo)準(zhǔn)試劑,Spectrum試劑,美國藥典級試劑等

    資料下載您現(xiàn)在的位置:首頁 > 資料下載 > 人腫瘤壞死因子α(TNF-α)說明書
    人腫瘤壞死因子α(TNF-α)說明書
    發(fā)布時間:2016/5/16   點擊次數(shù):4946次

     

    Human TNF-α

     

    FOR RESEARCH USE ONLY

     

     

    Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

     

    Purpose

     

    This kit allows for the determination of TNF-α concentrations in Human serum.

     

     

    Principle of the assay

     

    The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

     

    Materials provided with the kit

     

    1

    washsolution

    20ml×1bottle

    7

    Stop Solution

    6ml×1 bottle

     

     

     

     

     

     

    2

    HRP-Conjugate reagent

    6ml×1 bottle

    8

    Standard800ng/L

    0.5ml×1 bottle

     

     

     

     

     

     

    3

    Microelisa stripplate

    12well×8strips

    9

    Standard diluent

    1.5ml×1bottle

     

     

     

     

     

     

    4

    Sample diluent

    6ml×1 bottle

    10

    Instruction

    1

     

     

     

     

     

     

    5

    Chromogen Solution A

    6ml×1 bottle

    11

    Closure plate

    2

    membrane

     

     

     

     

     

    6

    Chromogen Solution B

    6ml×1 bottle

    12

    Sealed bags

    1

     

     

     

     

     

     

     

    Specimen requirements

     

    • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

     

    1

     

     

    2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

     

    Assay procedure

     

    1. Dilute and add sample:Dilute Original density Standard as follow table:

     

    400ng/L

    5

    Standard

    150µl Original density Standard+150µl Standard diluent

     

     

     

     

     

    200ng/L

    4

    Standard

    150µl 5 Standard+150µl Standard diluent

     

     

     

     

     

    100ng/L

    3

    Standard

    150µl 4 Standard+150µl Standard diluent

     

     

     

     

     

    50ng/L

    2

    Standard

    150µl 3 Standard +150µl Standard diluent

     

     

     

     

     

    25ng/L

    1

    Standard

    150µl 2 Standard +150µl Standard diluent

     

     

     

     

     

     

    2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

     

    3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

     

    water and reserve.

     

    5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

     

    6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

     

    8.washingOperation with 5.

     

    9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

     

    10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

     

    11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

     

    within 15min.

     

    Steps description

     

     

     

     

    2

     

     

    Standard, Sample diluent

     

     

     

     

     

     

     

    Add Standard, Sample diluent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

     

     

     

     

     

     

     

    Add Stopp Solution

     

     

     

     

     

     

     

    Read absorbance at 450nm within 15 min

     

     

     

     

     

     

     

    calculate

     

    Calculate

     

    Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

     

    3

     

     

    the result is the sample actual density.

     

    Important notes

     

    • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

     

    • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

     

    • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

     

    • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

     

    • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

     

    • The substrate evade the light preservation.

     

    • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

     

    • All samples, washing buffer and each kind of reject should according to infective material process.

     

    • Do not mix reagents with those from other lots.

     

     

     

    Storage and validity

     

    1Storage 2-8.

     

    2validity six months

     

     

     

     

     

     

     

     

     

     

     

    4

     

    Human TNF-α

     

    FOR RESEARCH USE ONLY

     

     

    Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

     

    Purpose

     

    This kit allows for the determination of TNF-α concentrations in Human serum.

     

     

    Principle of the assay

     

    The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

     

    Materials provided with the kit

     

    1

    washsolution

    20ml×1bottle

    7

    Stop Solution

    6ml×1 bottle

     

     

     

     

     

     

    2

    HRP-Conjugate reagent

    6ml×1 bottle

    8

    Standard800ng/L

    0.5ml×1 bottle

     

     

     

     

     

     

    3

    Microelisa stripplate

    12well×8strips

    9

    Standard diluent

    1.5ml×1bottle

     

     

     

     

     

     

    4

    Sample diluent

    6ml×1 bottle

    10

    Instruction

    1

     

     

     

     

     

     

    5

    Chromogen Solution A

    6ml×1 bottle

    11

    Closure plate

    2

    membrane

     

     

     

     

     

    6

    Chromogen Solution B

    6ml×1 bottle

    12

    Sealed bags

    1

     

     

     

     

     

     

     

    Specimen requirements

     

    • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

     

    1

     

     

    2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

     

    Assay procedure

     

    1. Dilute and add sample:Dilute Original density Standard as follow table:

     

    400ng/L

    5

    Standard

    150µl Original density Standard+150µl Standard diluent

     

     

     

     

     

    200ng/L

    4

    Standard

    150µl 5 Standard+150µl Standard diluent

     

     

     

     

     

    100ng/L

    3

    Standard

    150µl 4 Standard+150µl Standard diluent

     

     

     

     

     

    50ng/L

    2

    Standard

    150µl 3 Standard +150µl Standard diluent

     

     

     

     

     

    25ng/L

    1

    Standard

    150µl 2 Standard +150µl Standard diluent

     

     

     

     

     

     

    2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

     

    3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

     

    water and reserve.

     

    5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

     

    6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

     

    8.washingOperation with 5.

     

    9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

     

    10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

     

    11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

     

    within 15min.

     

    Steps description

     

     

     

     

    2

     

     

    Standard, Sample diluent

     

     

     

     

     

     

     

    Add Standard, Sample diluent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

     

     

     

     

     

     

     

    Add Stopp Solution

     

     

     

     

     

     

     

    Read absorbance at 450nm within 15 min

     

     

     

     

     

     

     

    calculate

     

    Calculate

     

    Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

     

    3

     

     

    the result is the sample actual density.

     

    Important notes

     

    • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

     

    • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

     

    • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

     

    • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

     

    • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

     

    • The substrate evade the light preservation.

     

    • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

     

    • All samples, washing buffer and each kind of reject should according to infective material process.

     

    • Do not mix reagents with those from other lots.

     

     

     

    Storage and validity

     

    1Storage 2-8.

     

    2validity six months

     

     

     

     

     

     

    Human TNF-α

     

    FOR RESEARCH USE ONLY

     

     

    Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

     

    Purpose

     

    This kit allows for the determination of TNF-α concentrations in Human serum.

     

     

    Principle of the assay

     

    The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

     

    Materials provided with the kit

     

    1

    washsolution

    20ml×1bottle

    7

    Stop Solution

    6ml×1 bottle

     

     

     

     

     

     

    2

    HRP-Conjugate reagent

    6ml×1 bottle

    8

    Standard800ng/L

    0.5ml×1 bottle

     

     

     

     

     

     

    3

    Microelisa stripplate

    12well×8strips

    9

    Standard diluent

    1.5ml×1bottle

     

     

     

     

     

     

    4

    Sample diluent

    6ml×1 bottle

    10

    Instruction

    1

     

     

     

     

     

     

    5

    Chromogen Solution A

    6ml×1 bottle

    11

    Closure plate

    2

    membrane

     

     

     

     

     

    6

    Chromogen Solution B

    6ml×1 bottle

    12

    Sealed bags

    1

     

     

     

     

     

     

     

    Specimen requirements

     

    • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

     

    1

     

     

    2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

     

    Assay procedure

     

    1. Dilute and add sample:Dilute Original density Standard as follow table:

     

    400ng/L

    5

    Standard

    150µl Original density Standard+150µl Standard diluent

     

     

     

     

     

    200ng/L

    4

    Standard

    150µl 5 Standard+150µl Standard diluent

     

     

     

     

     

    100ng/L

    3

    Standard

    150µl 4 Standard+150µl Standard diluent

     

     

     

     

     

    50ng/L

    2

    Standard

    150µl 3 Standard +150µl Standard diluent

     

     

     

     

     

    25ng/L

    1

    Standard

    150µl 2 Standard +150µl Standard diluent

     

     

     

     

     

     

    2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

     

    3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

     

    water and reserve.

     

    5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

     

    6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

     

    8.washingOperation with 5.

     

    9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

     

    10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

     

    11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

     

    within 15min.

     

    Steps description

     

     

     

     

    2

     

     

    Standard, Sample diluent

     

     

     

     

     

     

     

    Add Standard, Sample diluent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

     

     

     

     

     

     

     

    Add Stopp Solution

     

     

     

     

     

     

     

    Read absorbance at 450nm within 15 min

     

     

     

     

     

     

     

    calculate

     

    Calculate

     

    Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

     

    3

     

     

    the result is the sample actual density.

     

    Important notes

     

    • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

     

    • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

     

    • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

     

    • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

     

    • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

     

    • The substrate evade the light preservation.

     

    • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

     

    • All samples, washing buffer and each kind of reject should according to infective material process.

     

    • Do not mix reagents with those from other lots.

     

     

     

    Storage and validity

     

    1Storage 2-8.

     

    2validity six months

     

     

     

     

     

     

    Human TNF-α

     

    FOR RESEARCH USE ONLY

     

     

    Assay range20 ng/L -400 ng/L 96 DETERMINATIONS

     

    Purpose

     

    This kit allows for the determination of TNF-α concentrations in Human serum.

     

     

    Principle of the assay

     

    The kit assay Human TNF-α level in the sample, use Purified Human TNF-α antibody to coat microtiter plate wells, make solid-phase antibody, then add TNF-α to wells, Combined TNF-α antibody which With HRP labeled, become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Human TNF-α in the samples is then determined by comparing the O.D. of the samples to the standard curve.

     

    Materials provided with the kit

     

    1

    washsolution

    20ml×1bottle

    7

    Stop Solution

    6ml×1 bottle

     

     

     

     

     

     

    2

    HRP-Conjugate reagent

    6ml×1 bottle

    8

    Standard800ng/L

    0.5ml×1 bottle

     

     

     

     

     

     

    3

    Microelisa stripplate

    12well×8strips

    9

    Standard diluent

    1.5ml×1bottle

     

     

     

     

     

     

    4

    Sample diluent

    6ml×1 bottle

    10

    Instruction

    1

     

     

     

     

     

     

    5

    Chromogen Solution A

    6ml×1 bottle

    11

    Closure plate

    2

    membrane

     

     

     

     

     

    6

    Chromogen Solution B

    6ml×1 bottle

    12

    Sealed bags

    1

     

     

     

     

     

     

     

    Specimen requirements

     

    • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

     

    1

     

     

    2. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

     

    Assay procedure

     

    1. Dilute and add sample:Dilute Original density Standard as follow table:

     

    400ng/L

    5

    Standard

    150µl Original density Standard+150µl Standard diluent

     

     

     

     

     

    200ng/L

    4

    Standard

    150µl 5 Standard+150µl Standard diluent

     

     

     

     

     

    100ng/L

    3

    Standard

    150µl 4 Standard+150µl Standard diluent

     

     

     

     

     

    50ng/L

    2

    Standard

    150µl 3 Standard +150µl Standard diluent

     

     

     

     

     

    25ng/L

    1

    Standard

    150µl 2 Standard +150µl Standard diluent

     

     

     

     

     

     

    2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40µl to testing sample well, then add testing sample 10µl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

     

    3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37. 4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

     

    water and reserve.

     

    5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

     

    6.add enzymeAdd HRP-Conjugate reagent 50µl to each well, except blank well. 7.incubateOperation with 3.

     

    8.washingOperation with 5.

     

    9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 10 min at 37

     

    10.Stop the reactionAdd Stop Solution50µl to each well, Stop the reaction(the blue color change to yellow color).

     

    11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and

     

    within 15min.

     

    Steps description

     

     

     

     

    2

     

     

    Standard, Sample diluent

     

     

     

     

     

     

     

    Add Standard, Sample diluent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

     

     

     

     

     

     

     

    Wash 5 times,Add Chromogen Solution A and B, incubate for 10 min at 37.

     

     

     

     

     

     

     

    Add Stopp Solution

     

     

     

     

     

     

     

    Read absorbance at 450nm within 15 min

     

     

     

     

     

     

     

    calculate

     

    Calculate

     

    Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

     

    3

     

     

    the result is the sample actual density.

     

    Important notes

     

    • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

     

    • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

     

    • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

     

    • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

     

    • Closure plate membrane only limits the disposable use, to avoid cross-contamination.

     

    • The substrate evade the light preservation.

     

    • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

     

    • All samples, washing buffer and each kind of reject should according to infective material process.

     

    • Do not mix reagents with those from other lots.

     

     

     

    Storage and validity

     

    1Storage 2-8.

     

    2validity six

    文件下載    圖片下載    
    主站蜘蛛池模板: 亚洲一区二区三区免费| 久久久久亚洲Av片无码v| 日本免费一区二区三区最新| 亚洲国产精品13p| 亚洲永久中文字幕在线| 理论秋霞在线看免费| 久久大香香蕉国产免费网站| 真实乱视频国产免费观看| 国产成A人亚洲精V品无码| 亚洲精品精华液一区二区 | 337p日本欧洲亚洲大胆精品555588| 久久久久久亚洲精品无码| 国产亚洲综合一区二区三区| 午夜视频在线免费观看| 国产精品免费看久久久久| 亚洲一区二区三区在线| 久久久久久AV无码免费网站下载| 亚洲国产精久久久久久久| 黄视频在线观看免费| 全黄a免费一级毛片人人爱| 亚洲特级aaaaaa毛片| 成年18网站免费视频网站| 亚洲国产精品久久| 国产免费一区二区三区| 久久精品国产亚洲AV果冻传媒| 一区二区3区免费视频| 日韩视频免费在线| 亚洲免费视频一区二区三区| 99久久免费精品国产72精品九九| 久久久久亚洲av无码专区喷水| 久久成人18免费网站| 久久亚洲AV成人出白浆无码国产| 欧美男同gv免费网站观看| 一道本在线免费视频| 久久水蜜桃亚洲av无码精品麻豆| 成人免费淫片在线费观看| 国产精品1024在线永久免费| 亚洲精品第一国产综合精品| 四虎永久在线精品免费影视| 鲁啊鲁在线视频免费播放| 香蕉蕉亚亚洲aav综合|